Kinetic Red Target Testing
From Anvita Health Wiki
Contents |
Indications
Procedure
- patients report their first perception of red color when a 5-mm red-topped pin is moved inward from the boundary of each visual quadrant
Notes
- 74% sensitivity, 93% specificity
- may be visual field test of choice
More General Terms
Additional Terms
References
- Kerr NM et al Diagnostic accuracy of confrontation visual field tests. Neurology 2010 Apr 13; 74:1184. PMID: [1]